Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Chinese Journal of Tissue Engineering Research ; (53): 9581-9584, 2008.
Article in Chinese | WPRIM | ID: wpr-406753

ABSTRACT

Prosthesis for femoral head surface replacement was designed. Between January 2002 and December 2005,28 patients underwent femoral head surface replacement in Anyang People's Hospital. The diameter of the normal femoral head was determined by CT,and the prosthesis was selected according to the measured value ±1 mm. With the muscle gap approach,the center of the femoral head was determined according to the measured distance between the femoral head center and the culminated point of the round ligament fossa based on the mark of the culminated point of the round ligament pit. Additionally,the diameter of the femoral head was measured again to ensure the precise match of the prosthesis and acetabulum. X-ray films at 24-48 months show no loosening or dislocation of the prosthesis,which was well matched with acetabulum. Furthermore,the joint space did not remarkably change. The mean score was 63 before operation and 91.5 after operation respectively according to Harris sore. The successful rate is 92.86% (excellent in 23cases,good in 3,and improved in 2). The results show that femoral head surface replacement is an effective method for young patients with avascular necrosis of the femoral head at the stage of ARCO HI.

SELECTION OF CITATIONS
SEARCH DETAIL